skip to main content

Title: Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3more » {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.« less
Authors:
; ;  [1] ; ;  [2]
  1. ARTORG Center for Biomedical Engineering Research, University of Bern (Switzerland)
  2. Innsbruck Medical University, Section of Microinvasive Therapy, Department of Radiology (Austria)
Publication Date:
OSTI Identifier:
22207964
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 36; Journal Issue: 6; Other Information: Copyright (c) 2013 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ACCURACY; COMPUTERIZED TOMOGRAPHY; DATASETS; EUCLIDEAN SPACE; IMAGES; LIVER; PHANTOMS; THERAPY; TITANIUM