Title: Monte Carlo-based simulation of dynamic jaws tomotherapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3626486· OSTI ID:22098624
; ; ; ; ;  [1]
  1. Department of Molecular Imaging, Radiotherapy and Oncology, Universite Catholique de Louvain, 54 Avenue Hippocrate, 1200 Brussels, Belgium and Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

OSTI ID:
22098624
Journal Information:
Medical Physics, Vol. 38, Issue 9; Other Information: (c) 2011 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English