The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a {+-}2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4{omega} (263 nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, titanium, gold, and silver photocathode materials have been tested. Aluminum showed the highest relative quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data were analyzed to determine the centroiding statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of {+-}1.6 ps and {+-}0.7 ps, respectively.

OSTI ID:
22093903
Journal Information:
Review of Scientific Instruments, Vol. 83, Issue 10; Other Information: (c) 2012 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English