skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Influence of Radiofrequency Ablation of Lung Cancer on Pulmonary Function

Journal Article · · Cardiovascular and Interventional Radiology
;  [1];  [2]; ;  [1];  [3];  [4];  [5];  [6];  [1]
  1. Okayama University Medical School, Department of Radiology (Japan)
  2. Fukuyama City Hospital, Department of Radiology (Japan)
  3. Okayama University Medical School, Department of Cancer and Thoracic Surgery (Japan)
  4. Okayama University Medical School, Department of Respiratory Medicine (Japan)
  5. Okayama University Graduate School, Department of Environmental Epidemiology, Graduate School of Environmental Science (Japan)
  6. Okayama University Medical School, Department of Epidemiology (Japan)

Purpose: The purpose of this study was to evaluate altered pulmonary function retrospectively after RFA. Methods: This retrospective study comprised 41 ablation sessions for 39 patients (22 men and 17 women; mean age, 64.8 years). Vital capacity (VC) and forced expiratory volume in 1 s (FEV{sub 1}) at 1 and 3 months after RFA were compared with the baseline (i.e., values before RFA). To evaluate the factors that influenced impaired pulmonary function, univariate analysis was performed by using multiple variables. If two or more variables were indicated as statistically significant by univariate analysis, these variables were subjected to multivariate analysis to identify independent factors. Results: The mean VC and FEV{sub 1} before RFA and 1 and 3 months after RFA were 3.04 and 2.24 l, 2.79 and 2.11 l, and 2.85 and 2.13 l, respectively. The values at 1 and 3 months were significantly lower than the baseline. Severe pleuritis after RFA was identified as the independent factor influencing impaired VC at 1 month (P = 0.003). For impaired FEV{sub 1} at 1 month, only severe pleuritis (P = 0.01) was statistically significant by univariate analysis. At 3 months, severe pleuritis (VC, P = 0.019; FEV{sub 1}, P = 0.003) and an ablated parenchymal volume {>=}20 cm{sup 3} (VC, P = 0.047; FEV{sub 1}, P = 0.038) were independent factors for impaired VC and FEV{sub 1}. Conclusions: Pulmonary function decreased after RFA. RFA-induced severe pleuritis and ablation of a large volume of marginal parenchyma were associated with impaired pulmonary function.

OSTI ID:
22066596
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 35, Issue 4; Other Information: Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English