Title: Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Mod

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3478634· OSTI ID:22058712
;  [1]
  1. Plasma Science and Fusion Center, Massachusetts Institute of Technology, 77 Massachusetts Ave., NW17-155, Cambridge, Massachusetts 02139 (United States)

The ideal in situ plasma facing component (PFC) diagnostic for magnetic fusion devices would perform surface element and isotope composition measurements on a shot-to-shot ({approx}10 min) time scale with {approx}1 {mu}m depth and {approx}1 cm spatial resolution over large areas of PFCs. To this end, the experimental adaptation of the customary laboratory surface diagnostic - nuclear scattering of MeV ions - to the Alcator C-Mod tokamak is being guided by ACRONYM, a Geant4 synthetic diagnostic. The diagnostic technique and ACRONYM are described, and synthetic measurements of film thickness for boron-coated PFCs are presented.

OSTI ID:
22058712
Journal Information:
Review of Scientific Instruments, Vol. 81, Issue 10; Other Information: (c) 2010 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748