Studies of emittance of multiply charged ions extracted from high temperature superconducting electron cyclotron resonance ion source, PKDELIS
- Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India)
- Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)
For the high current injector project at Inter University Accelerator Centre, a high temperature superconducting electron cyclotron resonance (ECR) ion source, PKDELIS, would provide the high charge state ions. The emittance of the ECR ion source is an important parameter to design further beam transport system and to match the acceptances of the downstream radio frequency quadrupole and drift tube linac accelerators of the high current injector. The emittance of the analyzed beam of PKDELIS ECR source has been measured utilizing the three beam size technique. A slit and two beam profile monitors positioned at fixed distances from each other were used to measure the beam size. The digitized beam profiles have been analyzed to determine the emittance of various multiply charged ions. The variation of emittance with gas mixing, ultrahigh frequency power, and extraction energy are discussed in this presentation.
- OSTI ID:
- 22053898
- Journal Information:
- Review of Scientific Instruments, Vol. 81, Issue 2; Conference: ICIS 2009: 13. international conference on ion sources, Gatlinburg, TN (United States), 20-25 Sep 2009; Other Information: (c) 2010 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of source tuning parameters on the plasma potential of heavy ions in the 18 GHz high temperature superconducting electron cyclotron resonance ion source
Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source