skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Upgrade and validation on plasma of the Tore Supra CW LHCD generator

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.3664949· OSTI ID:21612472

A one year-long major upgrade of the 3.7 GHz Lower Hybrid Current Drive (LHCD) generator for the Tore Supra (TS) tokamak has been performed. It consisted in installing a first series of eight Thales Electron Devices (TED) 700 kW CW klystrons, new CW components and auxiliaries, and in modifying the transmitter control and protection software. Modifications and calibration of the sensors and the RF subsystems were completed as well. Finally, the RF power available in the generator has been increased by 35% and the pulse duration could reach 1000 s. A complete validation and optimization of the klystrons have been performed in 2010 on matched load before the generator could enter into operation. The eight klystrons connected with the Full Active Multijunction (FAM) antenna delivered 3.5 MW/50s in December 2010. The upgrade of the generator and the steps to validate the modifications are described.

OSTI ID:
21612472
Journal Information:
AIP Conference Proceedings, Vol. 1406, Issue 1; Conference: 9. topical conference on radio frequency power in plasmas, Newport (United States), 1-3 Jun 2011; Other Information: DOI: 10.1063/1.3664949; (c) 2011 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English