skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Transarterial Ethylene Vinyl Alcohol Copolymer Visualization and Penetration After Embolization of Life-Threatening Hemoptysis: Technical and Clinical Outcomes

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2];  [3]; ; ; ;  [1]
  1. CHU of Montpellier, Arnaud de Villeneuve Hospital, Department of Radiology (France)
  2. CHU of Montpellier, Arnaud de Villeneuve Hospital, Department of Respiratory Diseases (France)
  3. Centre Hospitalier de l'Universite de Montreal, Notre-Dame Hospital, Department of Radiology (Canada)

Objectives: This study was designed to evaluate the feasibility of using ethylene vinyl alcohol copolymer (EVAC) for bronchial artery embolization (BAE) in patients with life-threatening hemoptysis and to compare the visualization and transarterial penetration of EVAC under fluoroscopy and computed tomography (CT). Methods: Fifteen patients (mean age, 62.9 (range, 24-82) years) who were referred for life-threatening hemoptysis (27 month period) underwent BAE using EVAC. All patients had thoracic CT examination before and after BAE. Technical and clinical results were evaluated. Visibility and extent of cast penetration (graded 1-4) on fluoroscopy and postprocedure CT were assessed and compared. Results: BAE was feasible in all but one artery (due to spasm; n = 27; 96.4%). No procedure-related complications or deaths were detected. Two patients had recurrent bleeding in the following day (13.3%). Immediate clinical success was achieved in 14 cases (93.3%) after reembolization of pulmonary artery pseudoaneurysm in one patient (mean follow-up, 43.5 (range, 14-148) days). Visibility of the cast was possible in 73.3% of patients (n = 11) under fluoroscopy (mean cast penetration 1.66) and in all patients under CT (mean cast penetration 2.06). The postinjection fluoroscopic visibility in 6 of 15 (40%) patients was inferior to CT (P < 0.02). Conclusions: BAE with EVAC seems to be feasible and safe with immediate control of hemoptysis in most patients. The postinjection fluoroscopic visibility of EVAC under fluoroscopy was inferior to CT.

OSTI ID:
21608511
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 35, Issue 3; Other Information: DOI: 10.1007/s00270-011-0270-3; Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English