A Pelvic Phantom for Modeling Internal Organ Motions
- Institute of Oncotherapy, University of Pecs, Pecs (Hungary)
- Oncotherapy Clinic, University of Szeged, Szeged (Hungary)
- Department of Radiology, University of Pecs, Pecs (Hungary)
A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.
- OSTI ID:
- 21590477
- Journal Information:
- Medical Dosimetry, Vol. 36, Issue 3; Other Information: DOI: 10.1016/j.meddos.2010.04.002; PII: S0958-3947(10)00063-4; Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0958-3947
- Country of Publication:
- United States
- Language:
- English
Similar Records
Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy
Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy
Related Subjects
BLADDER
CAT SCANNING
DOSIMETRY
IRRADIATION
NEOPLASMS
PHANTOMS
PROSTATE
RADIATION DOSES
RADIOTHERAPY
RECTUM
SIMULATION
BODY
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
DIGESTIVE SYSTEM
DISEASES
DOSES
GASTROINTESTINAL TRACT
GLANDS
INTESTINES
LARGE INTESTINE
MALE GENITALS
MEDICINE
MOCKUP
NUCLEAR MEDICINE
ORGANS
RADIOLOGY
STRUCTURAL MODELS
THERAPY
TOMOGRAPHY
URINARY TRACT