skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Assay of PCM Crates and Drums using the BIL Solutions Ltd. Imaging DISPIM{sup R} System

Abstract

BIL Solutions Ltd Decommissioning In-Situ Plutonium Inventory Monitor (DISPIM{sup R}) is a versatile neutron and gamma assay system designed to be deployable in a wide range of decommissioning and waste management situations. The system utilizes Totals and Coincidence neutron counting to determine both total Pu mass values and the 3D Pu mass distribution inside the target object. DISPIM{sup R}'s modular, mobile design allows the system to be used in the assay of a range of objects of varying size and shape in locations where alternative monitoring equipment would not normally be available. The DISPIM{sup R} system has recently been successfully used for the in-situ measurement of crated and drummed Plutonium Contaminated Material (PCM) waste items to provide Pu mass values in preparation for their treatment as part of a decommissioning program. A description of the operation of the DISPIM{sup R} system is given, including calibration of the system prior to the on-site survey, the measurement and quality control methodology employed during assay of waste items and discussion of the data analysis techniques. The results of 'imaging' measurements (i.e. Pu mass distribution results) recorded from the PCM crate measurements are likely to be of particular benefit when planning any future operationsmore » on these waste items. The results of this DISPIM{sup R} survey represent a complete solution for the customer with minimal requirement for use of their own resources. Technically substantiated Pu mass assay results have been provided which can now be easily adopted for use in criticality safety cases for the future treatment of these waste items. In summary, the DISPIM{sup R} system has successfully delivered a safe, fast and cost effective measurement solution to this challenging assay task and demonstrated its flexibility as a PCM monitoring system. (authors)« less

Authors:
;  [1]
  1. BIL Solutions Ltd., Hinton House, Risley, Warrington, WA3 6AT (United Kingdom)
Publication Date:
Research Org.:
WM Symposia, Inc., PO Box 13023, Tucson, AZ, 85732-3023 (United States)
OSTI Identifier:
21208695
Report Number(s):
INIS-US-09-WM-06227
TRN: US09V1006079482
Resource Type:
Conference
Resource Relation:
Conference: Waste Management 2006 Symposium - WM'06 - Global Accomplishments in Environmental and Radioactive Waste Management: Education and Opportunity for the Next Generation of Waste Management Professionals, Tucson, AZ (United States), 26 Feb - 2 Mar 2006; Other Information: Country of input: France; 1 ref
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 42 ENGINEERING; CALIBRATION; DATA ANALYSIS; DECOMMISSIONING; INVENTORIES; MONITORS; PLUTONIUM; QUALITY CONTROL; RADIOACTIVE WASTE MANAGEMENT; SITE CHARACTERIZATION

Citation Formats

Mulligan, A, and Sharpe, R J. Assay of PCM Crates and Drums using the BIL Solutions Ltd. Imaging DISPIM{sup R} System. United States: N. p., 2006. Web.
Mulligan, A, & Sharpe, R J. Assay of PCM Crates and Drums using the BIL Solutions Ltd. Imaging DISPIM{sup R} System. United States.
Mulligan, A, and Sharpe, R J. 2006. "Assay of PCM Crates and Drums using the BIL Solutions Ltd. Imaging DISPIM{sup R} System". United States.
@article{osti_21208695,
title = {Assay of PCM Crates and Drums using the BIL Solutions Ltd. Imaging DISPIM{sup R} System},
author = {Mulligan, A and Sharpe, R J},
abstractNote = {BIL Solutions Ltd Decommissioning In-Situ Plutonium Inventory Monitor (DISPIM{sup R}) is a versatile neutron and gamma assay system designed to be deployable in a wide range of decommissioning and waste management situations. The system utilizes Totals and Coincidence neutron counting to determine both total Pu mass values and the 3D Pu mass distribution inside the target object. DISPIM{sup R}'s modular, mobile design allows the system to be used in the assay of a range of objects of varying size and shape in locations where alternative monitoring equipment would not normally be available. The DISPIM{sup R} system has recently been successfully used for the in-situ measurement of crated and drummed Plutonium Contaminated Material (PCM) waste items to provide Pu mass values in preparation for their treatment as part of a decommissioning program. A description of the operation of the DISPIM{sup R} system is given, including calibration of the system prior to the on-site survey, the measurement and quality control methodology employed during assay of waste items and discussion of the data analysis techniques. The results of 'imaging' measurements (i.e. Pu mass distribution results) recorded from the PCM crate measurements are likely to be of particular benefit when planning any future operations on these waste items. The results of this DISPIM{sup R} survey represent a complete solution for the customer with minimal requirement for use of their own resources. Technically substantiated Pu mass assay results have been provided which can now be easily adopted for use in criticality safety cases for the future treatment of these waste items. In summary, the DISPIM{sup R} system has successfully delivered a safe, fast and cost effective measurement solution to this challenging assay task and demonstrated its flexibility as a PCM monitoring system. (authors)},
doi = {},
url = {https://www.osti.gov/biblio/21208695}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Jul 01 00:00:00 EDT 2006},
month = {Sat Jul 01 00:00:00 EDT 2006}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: