Title: Measurement of Indoor Radon-222 and Radon-220 Concentrations in Central Japan

A passive-type radon/thoron detector was used for measuring indoor radon and thoron concentrations at 90 dwellings in Aichi and Gifu prefectures in central Japan during 90 days from December, 2006 to March, 2007. The radon and thoron concentrations were 21.1 Bq/m3 and 25.1 Bq/m3, respectively. The dose due to radon and thoron in dwellings was roughly evaluated as 0.7 mSv/y and 2.4 mSv/y, respectively. The examination of the geological factor and house condition having an effect on indoor radon concentration was performed.
Authors:
;  [1] ; ; ; ;  [2]
  1. Graduate School of Health Science, Fujita Health University 1-98, Dengakugakubo, Kutsukake, Tyoake, Aichi, 470-1192 (Japan)
  2. National Institute of Radiological Sciences 4-9-1, Anagawa, Inage, Chiba 263-8555 (Japan)
Publication Date:
OSTI Identifier:
21152437
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 1034; Journal Issue: 1; Conference: NRE-VIII: 8. International symposium on the natural radiation environment, Buzios, RJ (Brazil), 7-12 Oct 2007; Other Information: DOI: 10.1063/1.2991205; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; ALPHA DETECTION; DIELECTRIC TRACK DETECTORS; ECOLOGY; GEOLOGY; HOUSES; JAPAN; RADIATION DOSES; RADIATION MONITORING; RADON; RADON 220; RADON 222