skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

Journal Article · · Cardiovascular and Interventional Radiology
; ;  [1];  [2];  [3];  [4]; ;  [5]
  1. Ansan Hospital, Korea University College of Medicine, Department of Radiology (Korea, Republic of)
  2. Korea University, Ansan Hospital, Department of Urology (Korea, Republic of)
  3. Korea University, Ansan Hospital, Department of Pathology (Korea, Republic of)
  4. Ewha Women's University, Mokdong Hospital, Department of Radiology (Korea, Republic of)
  5. Stanford University Medical Center, Department of Vascular and Interventional Radiology (United States)

The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted.

OSTI ID:
21094170
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 31, Issue 3; Other Information: DOI: 10.1007/s00270-007-9087-5; Copyright (c) 2008 Springer Science+Business Media, LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model
Journal Article · Sun Jul 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21094170

Memokath Metallic Stent in the Treatment of Transplant Kidney Ureter Stenosis or Occlusion
Journal Article · Fri Apr 15 00:00:00 EDT 2005 · Cardiovascular and Interventional Radiology · OSTI ID:21094170

Effect of Antithrombotic Agents on the Patency of PTFE-Covered Stents in the Inferior Vena Cava: An Experimental Study
Journal Article · Sat May 15 00:00:00 EDT 1999 · Cardiovascular and Interventional Radiology · OSTI ID:21094170