Title: Thyroid Dose During Neurointerventional Procedures: Does Lead Shielding Reduce the Dose?

Journal Article · · Cardiovascular and Interventional Radiology

Purpose. To assess radiation dose to the thyroid in patients undergoing neurointerventional procedures and to evaluate dose reduction to the thyroid by lead shielding. Methods and Materials. A randomized patient study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. Sixty-five patients attending for endovascular treatment of arteriovenous malformations (AVMs) and aneurysms were randomized into one of 2 groups a) No Thyroid Shield and b) Thyroid Lead Shield. Two thermoluminescent dosimeters (TLDs) were placed over the thyroid gland (1 on each side) at constant positions on each patient in both groups. A thyroid lead shield (Pb eq. 0.5 mm) was placed around the neck of patients in the thyroid lead shield group after the neurointerventional radiologist had obtained satisfactory working access above the neck. The total dose-area-product (DAP) value, number and type of digital subtraction angiography (DSA) runs and fluoroscopy time were recorded for all patients. Results. Of the 72 patients who initially attended for neurointerventional procedures, 7 were excluded due to failure to consent or because of procedures involving access to the external carotid circulation. Of the remaining 65 who were randomized, a further 9 were excluded due to; procedureabandonment, unfeasible shield placement or shield interference with the procedure. Patient demographics included mean age of 47.9 yrs (15-74), F:M=1.4:1. Mean fluoroscopy time was 25.9 min. Mean DAP value was 13,134.8 cGy.cm{sup 2} and mean number of DSA runs was 13.4. The mean relative thyroid doses were significantly different (p< 0.001) between the unshielded (7.23 mSv/cGy2 x 105) and shielded groups (3.77 mSv/cGy2 x 105). A mean thyroid dose reduction of 48% was seen in the shielded group versus the unshielded group. Conclusion. Considerable doses to the thyroid are incurred during neurointerventional procedures, highlighting the need for increased awareness of patient radiation protection. Thyroid lead shielding yields significant radiation protection, is inexpensive and when not obscuring the field of view, should be used routinely.

OSTI ID:
21090806
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 30, Issue 5; Other Information: DOI: 10.1007/s00270-007-9093-7; Copyright (c) 2007 Springer Science+Business Media, LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:21090806

Occupational Radiation Exposure During Endovascular Aortic Repair
Journal Article · Sat Aug 15 00:00:00 EDT 2015 · Cardiovascular and Interventional Radiology · OSTI ID:21090806

Normalized dose data for upper gastrointestinal tract contrast studies performed to infants
Journal Article · Sat Apr 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:21090806