Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies
- University Hospital of Mainz, Johannes Gutenberg University of Mainz, Department of Diagnostic and Interventional Radiology (Germany)
- University Hospital of Mainz, Johannes Gutenberg University of Mainz, Department of Cardiovascular Surgery (Germany)
Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 {+-} 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 {+-} 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a satisfactory follow-up despite the necessity for reintervention and graft extension in 3 of 6 cases (50%). Two patients with type B dissection died due to mesenteric ischemia despite sufficient mesenteric blood flow being restored (but too late). Two suffered from neurologic complications, 1 from paraplegia and 1 from cerebral ischemia (probably embolic), 1 from penetrating ulcer, and 1 from persistent ischemia of the kidney. Five of 9 (56%) patients with symptomatic thoracic aneurysm demonstrated endoleaks during follow-up and there was an increase in the aneurysm in 1. Conclusion. Endovascular treatment is safe and effective for emergency treatment of life-threatening acute thoracic aortic syndromes. Results are encouraging, particularly for traumatic aortic ruptures. However, regular follow-up is mandatory, particularly in the other pathologies, to identify late complications of the stent-graft and to perform appropriate additional corrections as required.
- OSTI ID:
- 21090691
- Journal Information:
- Cardiovascular and Interventional Radiology, Vol. 31, Issue 1; Other Information: DOI: 10.1007/s00270-007-9175-6; Copyright (c) 2008 Springer Science+Business Media, LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft
Fenestrated Thoracic Endovascular Aortic Repair Using Physician-Modified Stent Grafts (PMSGs) in Zone 0 and Zone 1 for Aortic Arch Diseases