Title: Balloon Angioplasty Optimization: Should We Measure Balloon Volume As Well As Pressure?

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2]
  1. Bristol Royal Infirmary, Department of Radiology (United Kingdom)
  2. University of Ioannina Medical School, Department of Internal Medicine, Division of Cardiology (Greece)

Purpose. To investigate the influence that measurement of balloon volume as a controlled variable in addition to balloon pressure has on the outcome of balloon angioplasty in an experimental model. Methods. One hundred and three segments of explanted normal porcine carotid arteries were obtained. Five were used as controls, and the remaining 98 were subjected to balloon angioplasty with simultaneous measurement of balloon volume and pressure. These arteries were randomized into two groups. In one group the endpoint of the angioplasty was determined by balloon pressure (pressure-limited group, PLG) and in the other group by balloon volume (volume-limited group, VLG). Pressure/volume curves for each procedure were constructed by continuous measurement of both parameters by a purpose-designed computer-controlled inflation device. The diameter of each arterial segment was measured by intravascular ultrasound (IVUS) and the ratio of the inflated balloon to arterial diameter calculated. Arterial appearances after angioplasty were recorded using IVUS. Results. The balloon volumes measured at the endpoint of angioplasty were significantly smaller in the PLG compared with the VLG (p < 0.001). Three types of pressure/volume curves were identified: A, B, and C. In the type A curves, IVUS identified fissures in 28% (17/60) and the examination was normal in 72% (43/60). In the type B curves, IVUS identified fissures in 44% (4/9), dissections in 22% (2/9), and the examination was normal in 33% (3/9). In the type C curves, IVUS identified fissures in 44% (4/9) and dissection in 56% (5/9) with no normal examinations. In undamaged arterial segments a very high correlation was achieved between balloon volume and the balloon/artery ratio (Pearson correlation = -0.979, R{sup 2} = 0.957, p < 0.0001, n = 27). Conclusion. The measurement of pressure and volume during angioplasty enabled the construction of pressure/volume curves that showed deviations from the curves obtained in air. The balloon volume results, and significant deviation of the curve shape from the control curve shape, predicted vessel damage, which was confirmed by the IVUS appearance of the vessel after angioplasty. When pressure was used as the endpoint of balloon inflation the balloons were significantly underdilated compared with the manufacturer's nominal sizes. These data indicate that monitoring of pressure and volume during angioplasty may provide an alternative method of predicting vessel damage.

OSTI ID:
21090685
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 31, Issue 1; Other Information: DOI: 10.1007/s00270-007-9193-4; Copyright (c) 2008 Springer Science+Business Media, LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Dilatation Mechanism of Balloon Angioplasty in Children: Assessment by Angiography and Intravascular Ultrasound
Journal Article · Sun Mar 15 00:00:00 EST 1998 · Cardiovascular and Interventional Radiology · OSTI ID:21090685

Radiofrequency balloon angioplasty. Rationale and proof of principle
Journal Article · Tue Nov 01 00:00:00 EST 1988 · Invest. Radiol.; (United States) · OSTI ID:21090685

Effect of radiofrequency-generated thermal energy on the mechanical and histologic characteristics of the arterial wall in vivo: implications for radiofrequency angioplasty
Journal Article · Wed Feb 01 00:00:00 EST 1989 · Am. Heart J.; (United States) · OSTI ID:21090685