Title: Quantification of Horseradish Peroxidase Delivery into the Arterial Wall In Vivo as a Model of Local Drug Treatment: Comparison Between a Porous and a Gel-Coated Balloon Catheter

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900413· OSTI ID:21080276
;  [1];  [2];  [1];  [2]; ;  [1]
  1. Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, D-52057 Aachen (Germany)
  2. Department of Physiology, University of Technology Aachen, Pauwelsstrasse 30, D-52057 Aachen (Germany)

Purpose: To quantify horseradish peroxidase (HRP) delivery into the arterial wall, as a model of local drug delivery, and to compare two different percutaneous delivery balloons. Methods: Perforated and hydrophilic hydrogel-coated balloon catheters were used to deliver HRP in aqueous solution into the wall of porcine iliac arteries in vivo. HRP solutions of 1 mg/ml were used together with both perforated and hydrophilic hydrogel-coated balloon catheters and 40 mg/ml HRP solutions were used with the hydrogel-coated balloon only. The amount of HRP deposited in the arterial wall was then determined photospectrometrically. Results: Using the 1 mg/ml HRP solution, the hydrogel-coated balloon absorbed 0.047 mg HRP into the coating. Treatment with this balloon resulted in a mean vessel wall concentration of 7.4 {mu}g HRP/g tissue {+-} 93% (standard deviation) (n 7). Treatment with the hydrogel-coated balloon that had absorbed 1.88 mg HRP into the coating (using the 40 mg/ml HRP solution) led to a mean vessel wall concentration of 69.5 {mu}g HRP/g tissue {+-} 74% (n = 7). Treatment with the perforated balloon using 1 mg/ml aqueous HRP solution led to a mean vessel wall concentration of 174 {mu}g/g {+-} 81% (n = 7). Differences between the hydrogel-coated and perforated balloons (1 mg/g solutions of HRP) and between hydrogel-coated balloons (0.047 mg vs 1.88 mg absorbed into the balloon coating) were significant (p < 0.05; two-sided Wilcoxon test). Conclusions: The use of a perforated balloon catheter allowed the delivery of a higher total amount of HRP compared with the hydrogel-coated balloon, but at the cost of a higher systemic HRP application. To deliver 174 {mu}g HRP per gram of vessel wall with the perforated balloon, 6.5 {+-} 1.5 mg HRP were lost into the arterial blood (delivery efficiency range = 0.2%-0.3%). With 0.047 mg HRP loaded into the coating of the hydrogel balloon, 7.4 {mu}g HRP could be applied to 1 g of vessel wall (delivery efficiency 1.7%), and with 1.88 mg HRP loaded into the coating of the hydrogel balloon, 69.5 {mu}g HRP could be applied per gram of vessel wall (delivery efficiency 0.6%)

OSTI ID:
21080276
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 22, Issue 5; Other Information: DOI: 10.1007/s002709900413; Copyright (c) 1999 Springer-Verlag New York Inc; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English