Title: Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS)

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2756941· OSTI ID:20953512
; ; ; ; ; ;  [1]
  1. Department of Radiation Oncology, Physics, Duke University, DUMC 3295, Durham, North Carolina 27710 (United States)

Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 deg. to 40 deg. and acquisition times of less than 10 s. The resulting DTS slices show soft tissue contrast approaching that of full cone-beam CT. External beam radiotherapy target localization using DTS requires the registration of on-board DTS images with corresponding reference image data. This study evaluates three types of reference volume: original reference CT, exact reference DTS (RDTS), and a more computationally efficient approximate reference DTS (RDTS{sub approx}), as well as three different DTS scan angles (22 deg., 44 deg., and 65 deg.) for the DTS target localization task. Three-dimensional mutual information (MI) shared between reference and on-board DTS volumes was computed in a region surrounding the spine of a chest phantom, as translations spanning {+-}5 mm and rotations spanning {+-}5 deg. were simulated along each dimension in the reference volumes. The locations of the MI maxima were used as surrogates for registration accuracy, and the width of the MI peaks were used to characterize the registration robustness. The results show that conventional treatment planning CT volumes are inadequate reference volumes for direct registration with on-board DTS data. The efficient RDTS{sub approx} method also appears insufficient for MI-based registration without further refinement of the technique, though it may be suitable for manual registration performed by a human observer. The exact RDTS volumes, on the other hand, delivered a 3D DTS localization accuracy of 0.5 mm and 0.5 deg. along each axis, using only a single 44 deg. coronal on-board DTS scan of the chest phantom.

OSTI ID:
20953512
Journal Information:
Medical Physics, Vol. 34, Issue 8; Other Information: DOI: 10.1118/1.2756941; (c) 2007 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Automatic registration between reference and on-board digital tomosynthesis images for positioning verification
Journal Article · Fri Feb 15 00:00:00 EST 2008 · Medical Physics · OSTI ID:20953512

A dual-view digital tomosynthesis imaging technique for improved chest imaging
Journal Article · Tue Sep 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:20953512

Digital tomosynthesis with an on-board kilovoltage imaging device
Journal Article · Mon May 01 00:00:00 EDT 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20953512