Title: Resampling: An optimization method for inverse planning in robotic radiosurgery

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2357020· OSTI ID:20853688
; ;  [1]
  1. Institute of Robotics and Cognitive Systems, University of Luebeck, SH 23538 (Germany)

By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design permits a large number of distinct beam directions to be used in one single treatment. These major technical differences provide an opportunity to improve upon the well-established principles for treatment planning used with GammaKnife or LINAC radiosurgery. With this objective in mind, our group has developed over the past decade an inverse planning tool for robotic radiosurgery. This system first computes a set of beam directions, and then during an optimization step, weights each individual beam. Optimization begins with a feasibility query, the answer to which is derived through linear programming. This approach offers the advantage of completeness and avoids local optima. Final beam selection is based on heuristics. In this report we present and evaluate a new strategy for utilizing the advantages of linear programming to improve beam selection. Starting from an initial solution, a heuristically determined set of beams is added to the optimization problem, while beams with zero weight are removed. This process is repeated to sample a set of beams much larger compared with typical optimization. Experimental results indicate that the planning approach efficiently finds acceptable plans and that resampling can further improve its efficiency.

OSTI ID:
20853688
Journal Information:
Medical Physics, Vol. 33, Issue 11; Other Information: DOI: 10.1118/1.2357020; (c) 2006 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Shortening treatment time in robotic radiosurgery using a novel node reduction technique
Journal Article · Tue Mar 15 00:00:00 EDT 2011 · Medical Physics · OSTI ID:20853688

Variable Circular Collimator in Robotic Radiosurgery: A Time-Efficient Alternative to a Mini-Multileaf Collimator?
Journal Article · Tue Nov 01 00:00:00 EDT 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20853688

Stepwise multi-criteria optimization for robotic radiosurgery
Journal Article · Thu May 15 00:00:00 EDT 2008 · Medical Physics · OSTI ID:20853688