skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measurement uncertainties for vacuum standards at Korea Research Institute of Standards and Science

Journal Article · · Journal of Vacuum Science and Technology. A, International Journal Devoted to Vacuum, Surfaces, and Films
DOI:https://doi.org/10.1116/1.2244534· OSTI ID:20853533
; ;  [1]
  1. Vacuum Center, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

The Korea Research Institute of Standards and Science has three major vacuum systems: an ultrasonic interferometer manometer (UIM) (Sec. II, Figs. 1 and 2) for low vacuum, a static expansion system (SES) (Sec. III, Figs. 3 and 4) for medium vacuum, and an orifice-type dynamic expansion system (DES) (Sec. IV, Figs. 5 and 6) for high and ultrahigh vacuum. For each system explicit measurement model equations with multiple variables are, respectively, given. According to ISO standards, all these system variable errors were used to calculate the expanded uncertainty (U). For each system the expanded uncertainties (k=1, confidence level=95%) and relative expanded uncertainty (expanded uncertainty/generated pressure) are summarized in Table IV and are estimated to be as follows. For UIM, at 2.5-300 Pa generated pressure, the expanded uncertainty is <4.17x10{sup -2} Pa and the relative expanded uncertainty is <1.18x10{sup -2}; at 1-100 kPa generated pressure, the expanded uncertainty is <7.87 Pa and the relative expanded uncertainty is <7.84x10{sup -5}. For SES, at 3-100 Pa generated pressure, the expanded uncertainty is <1.77x10{sup -1} Pa and the relative expanded uncertainty is <1.81x10{sup -3}. For DES, at 4.6x10{sup -3}-1.3x10{sup -2} Pa generated pressure, the expanded uncertainty is <1.04x10{sup -4} Pa and the relative expanded uncertainty is <8.37x10{sup -3}; at 3.0x10{sup -6}-9.0x10{sup -4} Pa generated pressure, the expanded uncertainty is <8.21x10{sup -6} Pa and the relative expanded uncertainty is <1.37x10{sup -2}. Within uncertainty limits our bilateral and key comparisons [CCM.P-K4 (10 Pa-1 kPa)] are extensive and in good agreement with those of other nations (Fig. 8 and Table V)

OSTI ID:
20853533
Journal Information:
Journal of Vacuum Science and Technology. A, International Journal Devoted to Vacuum, Surfaces, and Films, Vol. 24, Issue 5; Other Information: DOI: 10.1116/1.2244534; (c) 2006 American Vacuum Society; Country of input: International Atomic Energy Agency (IAEA); ISSN 1553-1813
Country of Publication:
United States
Language:
English

Similar Records

Melting Investigation of the System BaF2-BaO-½Y2O3-CuOx-H2O
Journal Article · Sat Jan 01 00:00:00 EST 2005 · Superconductor Science & Technology · OSTI ID:20853533

Critical masses of bare metal spheres using SCALE/XSDRN
Journal Article · Sat Jul 01 00:00:00 EDT 2000 · Transactions of the American Nuclear Society · OSTI ID:20853533

First Results of the Search for Neutrinoless Double-Beta Decay with the NEMO 3 Detector
Journal Article · Fri Oct 28 00:00:00 EDT 2005 · Physical Review Letters · OSTI ID:20853533