Intravaginal high-dose-rate brachytherapy for stage I endometrial cancer: A randomized study of two dose-per-fraction levels
- Department of Gynecological Oncology, Oerebro University Hospital, Oerebro (Sweden)
- Department of Radiation Physics, Oerebro University Hospital, Oerebro (Sweden)
Purpose To compare two different fractionation schedules for postoperative vaginal high-dose-rate (HDR) irradiation in endometrial carcinomas. Methods and Materials In a complete geographic series of 290 low-risk endometrial carcinomas, the efficacy and side effects of two different fractionation schedules for postoperative vaginal irradiation were evaluated. The patients were treated during the years 1989-2003. The tumors were in International Federation of Gynecology and Obstetrics Stages IA-IB and Grades 1-2. The HDR MicroSelectron afterloading equipment (iridium-192) was used. Perspex vaginal applicators with diameters of 20-30 mm were used, and the dose was specified at 5 mm from the surface of the applicator. Six fractions were given, and the overall treatment time was 8 days. The size of the dose per fraction was randomly set to 2.5 Gy (total dose of 15.0 Gy) or 5.0 Gy (total dose of 30.0 Gy). One hundred forty-four patients were treated with the 2.5-Gy fraction and 146 patients with the 5.0-Gy fraction. Results The overall locoregional recurrence rate of the complete series was 1.4% and the rate of vaginal recurrences 0.7%. There was no difference between the two randomized groups. The vaginal shortening measured by colpometry was not significant (p = 0.159) in the 2.5-Gy group (mean, 0.3 cm) but was highly significant (p < 0.000001) in the 5.0-Gy group (mean 2.1 cm) after 5 years. Mucosal atrophy and bleedings were significantly more frequent in the 5.0-Gy group. Symptoms noted in the 2.5-Gy group were not different from what could be expected in a normal group of postmenopausal women. Conclusion The fractionation schedule recommended for postoperative vaginal irradiation in low-risk endometrial carcinoma is six fractions of 2.5 Gy when the HDR technique is used.
- OSTI ID:
- 20698495
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Vol. 62, Issue 5; Other Information: DOI: 10.1016/j.ijrobp.2004.12.079; PII: S0360-3016(05)00041-6; Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Intravaginal brachytherapy alone for intermediate-risk endometrial cancer
Three or Four Fractions of 4-5 Gy per Week in Postoperative High-Dose-Rate Brachytherapy for Endometrial Carcinoma