Development of a 3D Electromagnetic Model for Eddy Current Tubing Inspection: Application to Steam Generator Tubing
Journal Article
·
· AIP Conference Proceedings
- C.E.A. Saclay, 91191 Gif-sur-Yvette (France)
- I.R.S.N, 92262 Fontenay-aux-Roses (France)
In nuclear plants, the inspection of heat exchanger tubes is usually carried out by using eddy current nondestructive testing. A numerical model, based on a volume integral approach using the Green's dyadic formalism, has been developed, with support from the French Institute for Radiological Protection and Nuclear Safety, to predict the response of an eddy current bobbin coil to 3D flaws located in the tube's wall. With an aim of integrating this model into the NDE multi techniques platform CIVA, it has been validated with experimental data for 2D and 3D flaws.
- OSTI ID:
- 20632918
- Journal Information:
- AIP Conference Proceedings, Vol. 700, Issue 1; Conference: 30. annual review of progress in quantitative nondestructive evaluation, Green Bay, WI (United States), 27 Jul - 1 Aug 2003; Other Information: DOI: 10.1063/1.1711640; (c) 2004 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Computer-aided analysis of eddy current rotating probe data.
Advanced Eddy current NDE steam generator tubing.
Transmit-receive eddy current probes for defect detection and sizing in steam generator tubes
Conference
·
Thu Mar 07 00:00:00 EST 2002
·
OSTI ID:20632918
+1 more
Advanced Eddy current NDE steam generator tubing.
Conference
·
Mon Mar 29 00:00:00 EST 1999
·
OSTI ID:20632918
Transmit-receive eddy current probes for defect detection and sizing in steam generator tubes
Conference
·
Sat Feb 01 00:00:00 EST 1997
·
OSTI ID:20632918