skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental study and analysis on components of a thermoacoustic refrigerator and thermoacoustic prime mover

Conference ·
OSTI ID:20030437

A thermoacoustic refrigerator and a thermoacoustic prime mover, due to its simple structure, would serve as very desirable systems because thermoacoustic prime movers can be driven with the waste heat such as an exhaust gas from engines, and with heat from the nature such as sunlight and a geothermal heat. The thermoacoustic refrigerator and the thermoacoustic prime mover combined would serve as a perfect cooling system without moving parts, CFC's and HFC's. Thus this Thermoacoustic-driven Thermoacoustic Refrigerator will replace the previous paper compression refrigeration system. The authors set up the thermoacoustic refrigerator and thermoacoustic prime mover to investigate the fundamental characteristics. On the refrigerator tests, dimensions of the stack are varied as a parameter of experiments. As a result, influences of the stack configuration on the performance are confirmed, so the design method for the optimum dimension to attain the large temperature difference can be indicated. About the prime mover tests, fundamental characteristics of stack dimensions is checked. The way to improve the thermal efficiency of the prime mover is mentioned in terms of the operating condition. Numerical calculations about the refrigerator are made which is based on the enthalpy flow model by Radebaugh. The result of calculations has a good agreement in quality with the experimental results, so the propriety of this model is confirmed.

Research Organization:
Waseda Univ., Tokyo (JP)
OSTI ID:
20030437
Resource Relation:
Conference: 5th ASME/JSME Thermal Engineering Joint Conference, San Diego, CA (US), 03/14/1999--03/19/1999; Other Information: 1 CD-ROM. Operating system required: Windows i386(tm), i486(tm), Pentium (R) or Pentium Pro, MS Windows 3.1, 95, or NT 3.51, 8 MB RAM, MacIntosh and Power MacIntosh with a 68020 or greater processor, System software version 7.1, 3.5 MB RAM (5 MB for PowerMac) 6 MB available hard-disk space, Unix; PBD: 1999; Related Information: In: Proceedings of the 5th ASME/JSME thermal engineering joint conference, [3600] pages.
Country of Publication:
United States
Language:
English

Similar Records

Simulation studies on the standing and traveling wave thermoacoustic prime movers
Journal Article · Wed Jan 29 00:00:00 EST 2014 · AIP Conference Proceedings · OSTI ID:20030437

Measurements with reticulated vitreous carbon stacks in thermoacoustic prime movers and refrigerators
Journal Article · Wed Jul 01 00:00:00 EDT 1998 · Journal of the Acoustical Society of America · OSTI ID:20030437

Specific acoustic impedance measurements of an air-filled thermoacoustic prime mover
Journal Article · Tue Dec 01 00:00:00 EST 1992 · Journal of the Acoustical Society of America; (United States) · OSTI ID:20030437