Title: Improved low NOx firing systems for pulverized coal combustion

Conference ·
OSTI ID:20013459

More stringent emission limits or the addition of post combustion NOx control create the need for improvements of NOx emissions from pulverized coal boilers. Many boilers retrofitted with Low NOx technology during Phase 1 and Phase 2 of the CAAA fail or marginally meet their requirements. Technical solutions range from addition of overfire air and state-of-the-art low NOx burners to low cost additions of combustion enhancements. Regardless of the combustion NOx control method used, stoichiometries local to the burners must be maintained at the designed values at all times to provide high NOx performance at low efficiency loss due to unburned fuel. This paper describes Foster Wheeler's approach to NOx emission improvements for existing low NOx firing systems. The technology to measure air and coal flow individually for each burner and to control the parameters for optimum combustion are presented and discussed. Field experience shows the installation and advantages of the technology.

Research Organization:
Foster Wheeler Energy Corp., Clinton, NJ (US)
OSTI ID:
20013459
Resource Relation:
Conference: 24th International Technical Conference on Coal Utilization and Fuel Systems, Clearwater, FL (US), 03/08/1999--03/11/1999; Other Information: PBD: [1999]; Related Information: In: The proceedings of the 24th international technical conference on coal utilization and fuel systems, by Sakkestad, B.A. [ed.], 1091 pages.
Country of Publication:
United States
Language:
English