Title: Experimental investigation on distribution of heat flux in boiler of wall tangentially combustion with horizontal dense-dilute pulverized-coal concentration

Conference ·
OSTI ID:20006905

In this dissertation, burners are distributed on four walls of boiler for form Wall Tangentially Combustion with Horizontal Dense-Dilute P.C Stream, and test with Yibin anthracite coal is made. The experimental results show that near the middle of boiler walls, wall heat flux in boiler is maximum, and heat flux projected in the centers of four walls is 1.375 times of that in the corners. Meantime, maximum relative wall temperature difference in burner zone in the way of Wall Tangentially Combustion is 1/4.5 of corner tangentially combustion.

Research Organization:
Xian Jiaotong Univ. (CN)
OSTI ID:
20006905
Resource Relation:
Conference: 1999 International Joint Power Generation Conference, Burlingame, CA (US), 07/25/1999--07/28/1999; Other Information: PBD: 1999; Related Information: In: Proceedings of the 1999 international joint power generation conference (FACT-vol. 23). Volume 1: Fuels and combustion technologies; Gas turbines; and Nuclear engineering, by Penfield, S.R. Jr.; Moussa, N.A. [eds.], 651 pages.