skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Temperature measurements in an industrial furnace by spontaneous anti-Stokes Raman spectroscopy

Conference ·
OSTI ID:20002768

Spontaneous anti-Stokes Raman scattering from N{sub 2} was employed to measure the temperature profiles inside an industrial furnace with a water-cooled probe. Prior to the field measurements, the system performance was evaluated and maximized in a laboratory furnace at several temperatures below 1,300 K. The temperatures of about 1,500 K have been measured in the industrial furnace, and they are in agreement with data recorded with a thermocouple probe. Spontaneous anti-Stokes Raman was found to be a reliable tool for non-intrusive absolute temperature measurements in industrial furnaces with relatively clean gas streams. Little dependence was found on the laser power and optics mis-alignment.

Research Organization:
Mississippi State Univ., Starkville (US)
OSTI ID:
20002768
Resource Relation:
Conference: 33rd Intersociety Energy Conversion Engineering Conference, Colorado Springs, CO (US), 08/02/1998--08/06/1998; Other Information: 1 CD-ROM. Operating system required: Windows 3.x; Windows 95/NT; Macintosh; UNIX. All systems need 2X CD-ROM drive.; PBD: 1998; Related Information: In: Proceedings of the 33. intersociety energy conversion engineering conference, by Anghaie, S. [ed.], [2800] pages.
Country of Publication:
United States
Language:
English