Title: Tokamak physics experiment: Diagnostic windows study

We detail the study of diagnostic windows and window thermal stress remediation in the long-pulse, high-power Tokamak Physics Experiment (TPX) operation. The operating environment of the TPX diagnostic windows is reviewed, thermal loads on the windows estimated, and cooling requirements for the windows considered. Applicable window-cooling technology from other fields is reviewed and its application to the TPX windows considered. Methods for TPX window thermal conditioning are recommended, with some discussion of potential implementation problems provided. Recommendations for further research and development work to ensure performance of windows in the TPX system are presented.
Authors:
;
Publication Date:
OSTI Identifier:
130668
Report Number(s):
LA--13053-MS
ON: DE96002358; TRN: 96:000112
DOE Contract Number:
W-7405-ENG-36;AC02-76CH03073
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: Nov 1995
Research Org:
Los Alamos National Lab., NM (United States); Princeton Univ., NJ (United States)
Sponsoring Org:
USDOE, Washington, DC (United States)
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; PLASMA DIAGNOSTICS; WINDOWS; THERMAL STRESSES; COOLING; TOKAMAK DEVICES; HEAT TRANSFER