skip to main content

SciTech ConnectSciTech Connect

Title: Repetitive Cyclic Potentiodynamic Polarization Scan Results for Reduced Sample Volume Testing

This report is the compilation of data gathered after repetitively testing simulated tank waste and a radioactive tank waste sample using a cyclic potentiodynamic polarization (CPP) test method to determine corrosion resistance of metal samples. Electrochemistry testing of radioactive tank samples is often used to assess the corrosion susceptibility and material integrity of waste tank steel. Repetitive testing of radiological tank waste is occasionally requested at 222-S Laboratory due to the limited volume of radiological tank sample received for testing.
Authors:
 [1]
  1. Washington River Protection Solutions, Richland, WA (United States)
Publication Date:
OSTI Identifier:
1241885
Report Number(s):
LAB-RPT--15-00009 Rev 0
DOE Contract Number:
AC27-08RV14800
Resource Type:
Technical Report
Research Org:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Org:
USDOE Office of Environmental Management (EM)
Contributing Orgs:
Washington River Protection Solutions, Richland, WA (United States)
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES