skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Zero Energy Ready Home Multifamily Case Study Analysis

Technical Report ·
DOI:https://doi.org/10.2172/1238326· OSTI ID:1238326
 [1];  [1]
  1. Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

Two multifamily buildings planned in Climate Zone 4 were analyzed to determine the cost, energy and performance implications of redesigning them to comply with Zero Energy Ready Home, a recognition program of the U.S. Department of Energy. Energy modeling was conducted on one representative apartment in each building using BEopt. Construction costs were obtained from the developer and subcontractors to determine savings and cost increases over ENERGY STAR. It was found that seven items would be necessary to change to comply with ZERH criteria when starting from the original design which was compliant with ENERGY STAR version 3.0. Design changes were made to the exterior walls, domestic water heating system, duct protection, duct design, garage ventilation, and pest control to comply with ZERH requirements. Energy impacts of upgrading from the original design to ZERH resulted in 2 to 8% reduction in modeled source energy consumption, or 1.7 to 10.4 MMBtu per year, although the original design was already about 8% better than a design configured to minimum ENERGY STAR criteria. According to the BEopt analysis, annualized energy related costs of the ZERH design were slightly higher for the apartment and slightly lower for the townhome when compared to the original design.

Research Organization:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1238326
Report Number(s):
NREL/SR-5500-64762; DOE/GO-102016-4735
Country of Publication:
United States
Language:
English