skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Rod internal pressure quantification and distribution analysis using Frapcon

Technical Report ·
DOI:https://doi.org/10.2172/1235837· OSTI ID:1235837

This report documents work performed supporting the Department of Energy (DOE) Office of Nuclear Energy (NE) Fuel Cycle Technologies Used Fuel Disposition Campaign (UFDC) under work breakdown structure element 1.02.08.10, ST Analysis. In particular, this report fulfills the M4 milestone M4FT- 15OR0810036, Quantify effects of power uncertainty on fuel assembly characteristics, within work package FT-15OR081003 ST Analysis-ORNL. This research was also supported by the Consortium for Advanced Simulation of Light Water Reactors (http://www.casl.gov), an Energy Innovation Hub (http://www.energy.gov/hubs) for Modeling and Simulation of Nuclear Reactors under U.S. Department of Energy Contract No. DE-AC05-00OR22725. The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data (including modeling significant trips and downpowers), and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed which tracks inter-cycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB2) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rodspecific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rod without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd/MTU is determined to be the total fuel rod void volume and the amount of released fission gas in the fuel rod, respectively. Cumulative distribution functions (CDFs) are prepared from the distribution of RIP and CHS predictions for all standard and IFBA rods. The provided CDFs allow for the determination of the portion of WBN1 fuel rods that exceed a specified RIP or CHS limit. Results are separated into IFBA and standard rods so that the two groups may be analyzed individually. FRAPCON results are provided in sufficient detail to enable the recalculation of the RIP while considering any desired plenum gas temperature, total void volume, or total amount of gas present in the void volume. A method to predict the CHS from a determined or assumed RIP is also proposed, which is based on the approximately linear relationship between the CHS and the RIP. Finally, improvements to the computational methodology of FRAPCON are proposed.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1235837
Report Number(s):
ORNL/TM-2015/557; AF5865010; NEAF346; FCRD-UFD-2015-000636
Country of Publication:
United States
Language:
English

Similar Records

Rod Internal Pressure Distribution and Uncertainty Analysis Using FRAPCON
Journal Article · Mon Jan 02 00:00:00 EST 2017 · Nuclear Technology · OSTI ID:1235837

Rod Internal Pressure Distribution and Uncertainty Analysis Using FRAPCON
Journal Article · Fri Feb 03 00:00:00 EST 2017 · Nuclear Technology · OSTI ID:1235837

ROD INTERNAL PRESSURE QUANTIFICATION AND DISTRIBUTION ANALYSIS USING FRAPCON
Conference · Fri Jan 01 00:00:00 EST 2016 · OSTI ID:1235837