Title: First attempt of at-cavity cryogenic X-ray detection in a CEBAF cryomodule for field emission monitoring

We report on the first result of at-cavity X-ray detection in a CEBAF cryomodule for field emission monitoring. In the 8-cavity cryomodule F100, two silicon diodes were installed near the end flange of each cavity. Each cavity was individually tested during the cryomodule test in JLab’s cryomodule test facility. The behaviors of these at-cavity cryogenic X-ray detectors were compared with those of the standard ‘in air’ Geiger-Muller (G-M) tubes. Our initial experiments establish correlation between X-ray response of near diodes and the field emission source cavity in the 8-cavity string. For two out of these eight cavities, we also carried out at-cavity X-ray detection experiment during their vertical testing. The aim is to track field emission behavior uniquely from vertical cavity testing to horizontal cavity testing in the cryomodule. These preliminary results confirmed our expectation and warrant further effort toward the establishment of permanent at-cavity cryogenic X-ray detection for SRF development and operation.
Authors:
 [1] ;  [1] ;  [1] ;  [1]
  1. Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Publication Date:
OSTI Identifier:
1223433
Report Number(s):
JLAB-ACC--15-2072; DOE/OR/23177--3427
TRN: US1601423
DOE Contract Number:
AC05-06OR23177
Resource Type:
Conference
Resource Relation:
Conference: IPAC 2015, Richmond, VA (United States), 3-8 May 2015
Research Org:
Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Sponsoring Org:
USDOE Office of Science (SC), Nuclear Physics (NP) (SC-26)
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; SUPERCONDUCTING CAVITY RESONATORS; X-RAY DETECTION; FIELD EMISSION; X RADIATION; CEBAF ACCELERATOR; SILICON DIODES; MONITORING; TESTING; COMPARATIVE EVALUATIONS; CORRELATIONS; GEIGER-MUELLER COUNTERS