Title: SNF Interim Storage Canister Corrosion and Surface Environment Investigations

This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of spent nuclear fuel (SNF). Of particular concern is stress corrosion cracking (SCC), by which a through-wall crack could potentially form in a canister outer wall over time intervals that are shorter than possible dry storage times. In order for SCC to occur, three criteria must be met. A corrosive environment must be present on the canister surface, the metal must susceptible to SCC, and sufficient tensile stress to support SCC must be present through the entire thickness of the canister wall. SNL is currently evaluating the potential for each of these criteria to be met.
Authors:
 [1] ;  [1]
  1. Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Publication Date:
OSTI Identifier:
1221714
Report Number(s):
SAND2015--8102R
603969; TRN: US1500423
DOE Contract Number:
AC04-94AL85000
Resource Type:
Technical Report
Research Org:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org:
USDOE Office of Nuclear Energy (NE)
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 42 ENGINEERING; STRESS CORROSION; SPENT FUEL CASKS; WASTE STORAGE; SURFACES; WALLS; DRY STORAGE; PROGRESS REPORT; CRACKS; PERFORMANCE; STRESSES