Evaluation of glare at the Ivanpah Solar Electric Generating System
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sims Industries, LLC, Dayton, OH (United States)
The Ivanpah Solar Electric Generating System (ISEGS), located on I-15 about 40 miles (60 km) south of Las Vegas, NV, consists of three power towers 459 ft (140 m) tall and over 170,000 reflective heliostats with a rated capacity of 390 MW. In addition, reports of glare from the plant have been submitted by pilots and air traffic controllers and recorded by the Aviation Safety Reporting System and the California Energy Commission since 2013. Aerial and ground-based surveys of the glare were conducted in April, 2014, to identify the cause and to quantify the irradiance and potential ocular impacts of the glare. Results showed that the intense glare viewed from the airspace above ISEGS was caused by heliostats in standby mode that were aimed to the side of the receiver. Evaluation of the glare showed that the retinal irradiance and subtended source angle of the glare from the heliostats in standby were sufficient to cause significant ocular impact (potential for after-image) up to a distance of ~6 miles (10 km), but the values were below the threshold for permanent eye damage. Glare from the receivers had a low potential for after-image at all ground-based monitoring locations outside of the site boundaries. A Letter to Airmen has been issued by the Federal Aviation Administration to notify pilots of the potential glare hazards. Additional measures to mitigate the potential impacts of glare from ISGES are also presented and discussed.
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1214696
- Journal Information:
- Energy Procedia (Online), Vol. 69, Issue C; ISSN 1876-6102
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Web of Science
Duration of Afterimage Disability After Viewing Simulated Sun Reflections
|
journal | January 1969 |
Evaluation of Optical Radiation Hazards
|
journal | January 1973 |
Discomfort glare assessment and prevention for daylight applications in office environments
|
journal | August 2005 |
A Photographic Flux Mapping Method for Concentrating Solar Collectors and Receivers
|
journal | July 2012 |
Challenges in the design of concentrator photovoltaic (CPV) modules to achieve highest efficiencies
|
journal | December 2018 |
On the Path to SunShot: Advancing Concentrating Solar Power Technology Performance and Dispatchability. | report | March 2016 |
Similar Records
Visibility and Visual Characteristics of the Ivanpah Solar Electric Generating System Power Tower Facility
Tower Illuminance Model (TIM): Interactive Real-Time Flyover Simulation Tool to Evaluate Glare and Avian-Flux Hazards