Title: NSLS-II Radio Frequency Systems

The National Synchrotron Light Source II is a 3 GeV X-ray user facility commissioned in 2014. The NSLS-II RF system consists of the master oscillator, digital low level RF controllers, linac, booster and storage ring RF sub-systems, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system.
Authors:
; ; ; ; ; ;
Publication Date:
OSTI Identifier:
1195822
Report Number(s):
BNL--107927-2015-CP
R&D Project: LS001
DOE Contract Number:
DE-SC00112704
Resource Type:
Conference
Resource Relation:
Conference: 6th International Particle Accelerator Conference; Newport News, Virginia; 20150503 through 20150508
Research Org:
Brookhaven National Laboratory (BNL) National Synchrotron Light Source II
Sponsoring Org:
USDOE Office of Science (SC)
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS NSLS-II; 3 GeV; RF