Optics measurement and correction during acceleration with beta-squeeze in RHIC
Conference
·
OSTI ID:1183849
- Brookhaven National Lab. (BNL), Upton, NY (United States)
In the past, beam optics correction at RHIC has only taken place at injection and at final energy, with interpolation of corrections partially into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats that, if corrected, could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoiding the high-order multipole fields sampled by particles within the bunch. We recently demonstrated successful beam optics corrections during acceleration at RHIC. We verified conclusively the superior control of the beam realized via these corrections
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Nuclear Physics (NP)
- DOE Contract Number:
- SC00112704
- OSTI ID:
- 1183849
- Report Number(s):
- BNL-107308-2015-CP; R&D Project: KBCH139; 18035; KB0202011; TRN: US1500217
- Resource Relation:
- Conference: 6th International Particle Accelerator Conference (IPAC’15), Richmond, VA (United States), 3-8 May 2015
- Country of Publication:
- United States
- Language:
- English
Similar Records
Optics measurement and correction during beam acceleration in the Relativistic Heavy Ion Collider
Commissioning of a beta* knob for dynamic IR correction at RHIC
RHIC Polarized proton operation
Technical Report
·
Tue Sep 09 00:00:00 EDT 2014
·
OSTI ID:1183849
Commissioning of a beta* knob for dynamic IR correction at RHIC
Conference
·
Sun May 20 00:00:00 EDT 2012
·
OSTI ID:1183849
+1 more
RHIC Polarized proton operation
Conference
·
Mon Mar 28 00:00:00 EDT 2011
·
OSTI ID:1183849
+57 more