Title: Exploring Alternative Non-contact temperature measurements for 99Mo production facility NorthStar FY14 Activity 5, Deliverable 2

We have conducted an experiment to explore an alternative non-contact method of measuring the Inconel target window temperature. This experiment involves using a standard color camera to observe the visible light emitted from the Inconel target window at high heat in order to estimate the window temperature. The safety limit to prevent target window failure is 700 °C and therefore we need a reliable and accurate method of measuring temperature especially in the range of 600 °C to 700 °C if it is to replace the IR camera. In this temperature range the window will emit a significant amount of black body radiation within the visible range and hence the idea of using a color camera. The goal is to see if the shift in window color (determined by the RBG pixel values of the camera) as the target window is heated to 700 °C can be calibrated to the temperature.The reasons for exploring this as an alternative to an IR are camera are: significant cost reduction and potentially less complicated to calibrate.
Authors:
 [1] ;  [1]
  1. Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Publication Date:
OSTI Identifier:
1172205
Report Number(s):
LA-UR--15-21582
DOE Contract Number:
AC52-06NA25396
Resource Type:
Technical Report
Research Org:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Org:
USDOE National Nuclear Security Administration (NNSA)
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING Accelerator Design, Technology, and Operations; Atomic and Nuclear Physics