skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4913906· OSTI ID:1170585

The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray uences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-Kα and Kβ x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.

Research Organization:
Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States). Plasma Science and Fusion Center
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
NA0001857; NA0002035
OSTI ID:
1170585
Journal Information:
Review of Scientific Instruments, Vol. 86, Issue 3; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 11 works
Citation information provided by
Web of Science

Similar Records

Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas
Journal Article · Sun Mar 15 00:00:00 EDT 2015 · Review of Scientific Instruments · OSTI ID:1170585

Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics
Journal Article · Wed Dec 23 00:00:00 EST 2015 · Review of Scientific Instruments · OSTI ID:1170585

Empirical assessment of the detection efficiency of CR-39 at high proton fluence and a compact, proton detector for high-fluence applications
Journal Article · Mon Apr 14 00:00:00 EDT 2014 · Review of Scientific Instruments · OSTI ID:1170585