Title: SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-14-667-672 AND MCU-14-846-847: AUGUST AND SEPTEMBER 2014 MONTHLY SAMPLES

SRNL received two sets of SHT samples (MCU-14-667-672, pulled 8/27/2014 and MCU-14-846-847, pulled on 9/22/2014) for analysis. The samples were analyzed for composition. It is recommended that the solvent receives Isopar® L and TiDG trimming at this time. Analysis of sample MCU-14-846-847 indicates the solvent has evaporated Isopar®L and has lost TiDG to a level below the recommended minimum 1 mM level. Since the addition of MaxCalix to the SHT in early July 2014, the MaxCalix concentration in the solvent has reached nominal values. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.
Authors:
;
Publication Date:
OSTI Identifier:
1160328
Report Number(s):
SRNL-STI-2014-00502
DOE Contract Number:
DE-AC09-08SR22470
Resource Type:
Technical Report
Research Org:
SRS
Sponsoring Org:
DOE
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES MCU, ARP, ISDP, NGS