Title: The Hall D solenoid helium refrigeration system at JLab

Hall D, the new Jefferson Lab experimental facility built for the 12GeV upgrade, features a LASS 1.85 m bore solenoid magnet supported by a 4.5 K helium refrigerator system. This system consists of a CTI 2800 4.5 K refrigerator cold box, three 150 hp screw compressors, helium gas management and storage, and liquid helium and nitrogen storage for stand-alone operation. The magnet interfaces with the cryo refrigeration system through an LN2-shielded distribution box and transfer line system, both designed and fabricated by JLab. The distribution box uses a thermo siphon design to respectively cool four magnet coils and shields with liquid helium and nitrogen. We describe the salient design features of the cryo system and discuss our recent commissioning experience.
Authors:
 [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1]
  1. JLAB
Publication Date:
OSTI Identifier:
1132614
Report Number(s):
JLAB-ACE-13-1785; DOE/OR/23177-2995
DOE Contract Number:
AC05-06OR23177
Resource Type:
Conference
Resource Relation:
Journal Name: AIP Conf. Proc.; Journal Volume: 1573; Conference: ADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference - CEC, 17–21 June 2013, Anchorage, Alaska
Research Org:
Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Sponsoring Org:
USDOE Office of Science (SC)
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; 43 PARTICLE ACCELERATORS