skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Hanford Single-Shell Tank Leak Causes and Locations - 241-SX Farm

Technical Report ·
DOI:https://doi.org/10.2172/1114794· OSTI ID:1114794
 [1];  [1]
  1. Washington River Protection Solutions (United States)

This document identifies 241-SX Tank Farm (SX Farm) leak causes and locations for the 100 series leaking tanks (241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114, and 241-SX-115) identified in RPP-ENV-39658, Rev. 0, Hanford SX-Farm Leak Assessments Report. This document satisfies the SX Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

Research Organization:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM) (United States)
DOE Contract Number:
AC27-08RV14800
OSTI ID:
1114794
Report Number(s):
RPP-RPT-54910-Rev.0; TRN: US1400125
Country of Publication:
United States
Language: