skip to main content

Title: Analytical Results For MOX Colemanite Concrete Samples Received On November, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received two samples of colemanite concrete for analysis on November 21, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.
Authors:
Publication Date:
OSTI Identifier:
1111410
Report Number(s):
SRNL-STI--2013-00737
TRN: US1400057
DOE Contract Number:
DE-AC09-08SR22470
Resource Type:
Technical Report
Research Org:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org:
USDOE (United States)
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 36 MATERIALS SCIENCE; 61 RADIATION PROTECTION AND DOSIMETRY MOX, Colemanite Concrete