Title: Magnetoencephalography with a two-color pump probe atomic magnetometer.

Conference ·
OSTI ID:1021603

The authors have detected magnetic fields from the human brain with a compact, fiber-coupled rubidium spin-exchange-relaxation-free magnetometer. Optical pumping is performed on the D1 transition and Faraday rotation is measured on the D2 transition. The beams share an optical axis, with dichroic optics preparing beam polarizations appropriately. A sensitivity of <5 fT/{radical}Hz is achieved. Evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer. Recordings were validated by comparison with those taken by a commercial magnetoencephalography system. The design is amenable to arraying sensors around the head, providing a framework for noncryogenic, whole-head magnetoencephalography.

Research Organization:
Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1021603
Report Number(s):
SAND2010-4892C; TRN: US201117%%197
Resource Relation:
Conference: Proposed for presentation at the IEEE International Frequency Control Symposium 2010 held June 2-4, 2010 in Newport Beach, CA.
Country of Publication:
United States
Language:
English