Testing and evaluation of a moisture separator drain demineralizer at Davis-Besse Nuclear Station. Final report
Technical Report
·
OSTI ID:10143529
- Toledo Edison Co., Oak Harbor, OH (United States)
- B and W Nuclear Service Co., Lynchburg, VA (United States)
Davis-Besse operating data, obtained using the plant`s Chemistry Data Acquisition and Management System (CDAMS) show that by polishing 15--20% of the moisture separator drains the entire drain flow can be pumped forward, saving 5.4 MWe of plant output. Concurrently, the useful lifetimes of condensate polishers were extended by factors of about 6, reducing resin replacement costs by approximately $450,000 per year.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (United States); Toledo Edison Co., Oak Harbor, OH (United States); B and W Nuclear Service Co., Lynchburg, VA (United States)
- Sponsoring Organization:
- Electric Power Research Inst., Palo Alto, CA (United States)
- OSTI ID:
- 10143529
- Report Number(s):
- EPRI-TR-103833; ON: UN94010180; TRN: 94:007625
- Resource Relation:
- Other Information: PBD: Apr 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technical evaluation of the noise and isolation testing of the reactor protection system for the Davis Besse Nuclear Power Station, Unit 1
Pressure-dependent fragilities for piping components: Pilot study on Davis-Besse Nuclear Power Station
Summary of NUREG-1154: loss of main and auxiliary feedwater event at the Davis-Besse Plant on June 9, 1985
Technical Report
·
Tue Jan 01 00:00:00 EST 1980
·
OSTI ID:10143529
Pressure-dependent fragilities for piping components: Pilot study on Davis-Besse Nuclear Power Station
Technical Report
·
Mon Oct 01 00:00:00 EDT 1990
·
OSTI ID:10143529
+1 more
Summary of NUREG-1154: loss of main and auxiliary feedwater event at the Davis-Besse Plant on June 9, 1985
Journal Article
·
· Nucl. Saf.; (United States)
·
OSTI ID:10143529