skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Stripper foil failure modes and cures at the Spallation Neutron Source

Journal Article · · Physical Review Special Topics - Accelerators and Beams
OSTI ID:1011009

The Spallation Neutron Source comprises a 1 GeV, 1.4 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the $H^0$ excited states created during the $H^-$ charge exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming $H^-$ beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
DE-AC05-00OR22725
OSTI ID:
1011009
Journal Information:
Physical Review Special Topics - Accelerators and Beams, Vol. 14, Issue 030102; ISSN 1098-4402
Country of Publication:
United States
Language:
English

Similar Records

Stripper foil failure modes and cures at the Oak Rdige Spallation Neutron Source
Journal Article · Mon Mar 28 00:00:00 EDT 2011 · Physical Review Special Topics - Accelerators and Beams · OSTI ID:1011009

SNS Injection Foil Experience
Conference · Fri Jan 01 00:00:00 EST 2010 · OSTI ID:1011009

SNS STRIPPER FOIL FAILURE MODES AND THEIR CURES
Conference · Fri Jan 01 00:00:00 EST 2010 · OSTI ID:1011009