Title: Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids

Abstract

Microgrids have repeatedly demonstrated the ability to provide uninterrupted service to critical end-use loads during normal outages, severe weather events, and natural disasters. While their ability to provide critical services is well documented, microgrids present a more dynamic operational environment than grid-connected distribution systems. The electrodynamics of a microgrid are commonly driven by the high inertia of rotating generators, which are common in many microgrids. In such high-inertia systems, the impact of end-use load electromechanical dynamics are often not examined. However, with the increased penetration of inverter-based generation with little or no inertia, it is necessary to consider the impact that the dynamics of the end-use loads have on the operations of microgrids, particularly for a resiliency-based operation. These operations include, but are not limited to, switching operations, loss of generating units, and the starting of induction motors. This paper examines the importance of including multi-state electromechanical dynamic models of the end-use load when evaluating the operations of low inertia microgrids, and shows that by properly representing their behavior, it is possible to cost effectively size equipment while supporting resilient operations of critical end-use loads.

Authors:
 [1];  [1];  [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Seattle,, WA (United States)
Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Electricity (OE)
Contributing Org.:
Load modeling; Microgrids, Mathematical model; Power system dynamics; Induction motors; Transient analysis; Computational modeling
OSTI Identifier:
1438241
Alternate Identifier(s):
OSTI ID: 1429919
Report Number(s):
PNNL-SA-127268
Journal ID: ISSN 1949-3053
Grant/Contract Number:  
AC05-76RL01830
Resource Type:
Accepted Manuscript
Journal Name:
IEEE Transactions on Smart Grid
Additional Journal Information:
Journal Volume: 10; Journal Issue: 3; Journal ID: ISSN 1949-3053
Publisher:
IEEE
Country of Publication:
United States
Language:
English
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; 42 ENGINEERING; dynamics; electromechanical; GridLAB-D; induction motor; load model; microgrid; low inertia

Citation Formats

Tuffner, Francis K., Schneider, Kevin P., Hansen, Jacob, and Elizondo, Marcelo A. Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids. United States: N. p., 2018. Web. doi:10.1109/TSG.2018.2809452.
Tuffner, Francis K., Schneider, Kevin P., Hansen, Jacob, & Elizondo, Marcelo A. Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids. United States. https://doi.org/10.1109/TSG.2018.2809452
Tuffner, Francis K., Schneider, Kevin P., Hansen, Jacob, and Elizondo, Marcelo A. Wed . "Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids". United States. https://doi.org/10.1109/TSG.2018.2809452. https://www.osti.gov/servlets/purl/1438241.
@article{osti_1438241,
title = {Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids},
author = {Tuffner, Francis K. and Schneider, Kevin P. and Hansen, Jacob and Elizondo, Marcelo A.},
abstractNote = {Microgrids have repeatedly demonstrated the ability to provide uninterrupted service to critical end-use loads during normal outages, severe weather events, and natural disasters. While their ability to provide critical services is well documented, microgrids present a more dynamic operational environment than grid-connected distribution systems. The electrodynamics of a microgrid are commonly driven by the high inertia of rotating generators, which are common in many microgrids. In such high-inertia systems, the impact of end-use load electromechanical dynamics are often not examined. However, with the increased penetration of inverter-based generation with little or no inertia, it is necessary to consider the impact that the dynamics of the end-use loads have on the operations of microgrids, particularly for a resiliency-based operation. These operations include, but are not limited to, switching operations, loss of generating units, and the starting of induction motors. This paper examines the importance of including multi-state electromechanical dynamic models of the end-use load when evaluating the operations of low inertia microgrids, and shows that by properly representing their behavior, it is possible to cost effectively size equipment while supporting resilient operations of critical end-use loads.},
doi = {10.1109/TSG.2018.2809452},
journal = {IEEE Transactions on Smart Grid},
number = 3,
volume = 10,
place = {United States},
year = {Wed Mar 07 00:00:00 EST 2018},
month = {Wed Mar 07 00:00:00 EST 2018}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 18 works
Citation information provided by
Web of Science

Figures / Tables:

Figure 1 Figure 1: Single-phase motor state transition diagram

Save / Share: