Simulated building energy demand biases resulting from the use of representative weather stations
Abstract
Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Usingmore »
- Authors:
-
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Publication Date:
- Research Org.:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC), Biological and Environmental Research (BER)
- OSTI Identifier:
- 1413471
- Alternate Identifier(s):
- OSTI ID: 1701789
- Report Number(s):
- PNNL-SA-125597
Journal ID: ISSN 0306-2619; PII: S030626191731228X
- Grant/Contract Number:
- AC05-76RL01830
- Resource Type:
- Accepted Manuscript
- Journal Name:
- Applied Energy
- Additional Journal Information:
- Journal Volume: 209; Journal Issue: C; Journal ID: ISSN 0306-2619
- Publisher:
- Elsevier
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; building energy demand; representative cities; BEND; EnergyPlus; weather
Citation Formats
Burleyson, Casey D., Voisin, Nathalie, Taylor, Z. Todd, Xie, Yulong, and Kraucunas, Ian. Simulated building energy demand biases resulting from the use of representative weather stations. United States: N. p., 2017.
Web. doi:10.1016/J.APENERGY.2017.08.244.
Burleyson, Casey D., Voisin, Nathalie, Taylor, Z. Todd, Xie, Yulong, & Kraucunas, Ian. Simulated building energy demand biases resulting from the use of representative weather stations. United States. https://doi.org/10.1016/J.APENERGY.2017.08.244
Burleyson, Casey D., Voisin, Nathalie, Taylor, Z. Todd, Xie, Yulong, and Kraucunas, Ian. Mon .
"Simulated building energy demand biases resulting from the use of representative weather stations". United States. https://doi.org/10.1016/J.APENERGY.2017.08.244. https://www.osti.gov/servlets/purl/1413471.
@article{osti_1413471,
title = {Simulated building energy demand biases resulting from the use of representative weather stations},
author = {Burleyson, Casey D. and Voisin, Nathalie and Taylor, Z. Todd and Xie, Yulong and Kraucunas, Ian},
abstractNote = {Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20–40% bias of peak building loads during both summer and winter, a significant error for capacity expansion planners who may use these types of simulations. Using weather stations close to population centers reduces both mean and peak load biases. Our approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.},
doi = {10.1016/J.APENERGY.2017.08.244},
journal = {Applied Energy},
number = C,
volume = 209,
place = {United States},
year = {Mon Nov 06 00:00:00 EST 2017},
month = {Mon Nov 06 00:00:00 EST 2017}
}
Web of Science