DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab

Abstract

Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.

Authors:
 [1];  [1];  [1]
  1. Kharkov Institute of Physics and Technology, Kharkov (Ukraine)
Publication Date:
Research Org.:
Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Nuclear Physics (NP)
OSTI Identifier:
1222967
Report Number(s):
JLAB-PHY-14-2000; DOE/OR/23177-3574
Journal ID: ISSN 1562-6016
Grant/Contract Number:  
AC05-06OR23177
Resource Type:
Accepted Manuscript
Journal Name:
Voprosy Atomnoj Nauki i Tekhniki
Additional Journal Information:
Journal Volume: 2014; Journal ID: ISSN 1562-6016
Publisher:
Harʹkov : Nacionalʹnyj naučnyj centr, Harʹkovskij fiziko-tehničeskij institut
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Citation Formats

Vereshchaka, Vadym V., Glamazdin, Oleksandr V., and Pomatsalyuk, Roman I. Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab. United States: N. p., 2014. Web.
Vereshchaka, Vadym V., Glamazdin, Oleksandr V., & Pomatsalyuk, Roman I. Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab. United States.
Vereshchaka, Vadym V., Glamazdin, Oleksandr V., and Pomatsalyuk, Roman I. Tue . "Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab". United States. https://www.osti.gov/servlets/purl/1222967.
@article{osti_1222967,
title = {Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab},
author = {Vereshchaka, Vadym V. and Glamazdin, Oleksandr V. and Pomatsalyuk, Roman I.},
abstractNote = {Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.},
doi = {},
journal = {Voprosy Atomnoj Nauki i Tekhniki},
number = ,
volume = 2014,
place = {United States},
year = {Tue Jul 01 00:00:00 EDT 2014},
month = {Tue Jul 01 00:00:00 EDT 2014}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
The DOI is not currently available

Save / Share: