DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information
  1. Measurement of exclusive 𝜋+-argon interactions using ProtoDUNE-SP

    We present the measurement of 𝜋+-argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident 𝜋+ kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of 𝜋+-argonmore » secondary interactions within the liquid argon. This is the first measurement of 𝜋+-argon absorption at this kinetic energy range as well as the first ever measurement of 𝜋+-argon charge exchange.« less
  2. Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

    This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previouslymore » operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.« less
  3. The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

    Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta (0νββ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over fourmore » years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.« less
  4. Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

    The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonnemore » active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.« less
  5. Identification of low-energy kaons in the ProtoDUNE-SP detector

    The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment with a rich physics program that includes searches for the hypothetical phenomenon of proton decay. Utilizing liquid-argon time-projection chamber technology, DUNE is expected to achieve world-leading sensitivity in the proton decay channels that involve charged kaons in their final states. The first DUNE demonstrator, ProtoDUNE Single-Phase, was a 0.77 kt detector that operated from 2018 to 2020 at the CERN Neutrino Platform, exposed to a mixed hadron and electron test-beam with momenta ranging from 0.3 to 7 GeV/c. We present a selection of low-energy kaons among the secondary particlesmore » produced in hadronic reactions, using data from the 6 and 7 GeV/c beam runs. The selection efficiency is 1% and the sample purity 92%. The initial energies of the selected kaon candidates encompass the expected energy range of kaons originating from proton decay events in DUNE (below ∼200 MeV). In addition, we demonstrate the capability of this detector technology to discriminate between kaons and other particles such as protons and muons, and provide a comprehensive description of their energy loss in liquid argon, which shows good agreement with the simulation. These results pave the way for future proton decay searches at DUNE.« less
  6. Exploring the keV-scale physics potential of CUORE

    We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14  keV FWHM and 1.18more » ±0.02  keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05  counts/(keV kg days) and 16±2  counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.« less
  7. Publisher Erratum: A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

    In the originally published version of this article, several errors were identified in the author list and acknowledgements section. These have now been corrected as follows: Corrections to the Author List: Barrera has been corrected to Barresi. Copello (affiliation 18) has been corrected to Copello (affiliation 19). F. De Domizio has been corrected to S. Di Domizio. Figueros-Feliciamo has been corrected to Figueroa-Feliciano. Mancarella (affiliations 8, 17) has been corrected to Mancarella (affiliations 8, 18). Manenti (affiliations 18, 19) has been corrected to Manenti (affiliations 19, 20). Mayer (affiliations 3, 20, 31) has been corrected to Mayer (affiliations 3, 21,more » 31). Pagot has been corrected to Pageot. Puranam (affiliation 20) has been corrected to Puranam (affiliation 21). O. Penek has been corrected to Ö. Penek. L. Pettinacci has been corrected to V. Pettinacci. P. Pirro has been corrected to S. Pirro. Previtale has been corrected to Previtali. Rappoldi (affiliation 18) has been corrected to Rappoldi (affiliation 19). Raselli (affiliation 18) has been corrected to Raselli (affiliation 19). Rizzoli (affiliations 8, 17) has been corrected to Rizzoli (affiliations 8, 18). Rossella (affiliation 18) has been corrected to Rossella (affiliation 19). Correction to the Acknowledgements Section: The following grant numbers were missing and have now been added: This work was supported by NSF-PHY-2412377 and NSF-PHY-1913374. Additionally, on page 11, Section 5, second line, the chemical formula was incorrectly given as Li2MO4. The correct formula is Li2MoO4. The original article has been updated to reflect these corrections. The publisher apologizes for the inconvenience.« less
  8. Publisher Erratum: CUPID, the Cuore upgrade with particle identification

    Publisher Erratum: Eur. Phys. J. C (2025) 85:737 https://doi.org/10.1140/epjc/s10052-025-14352-1 The author M. Pavan (affiliations 9 and 10) was missing from the published author list. The online version of the article has been updated to include the author. Additionally, affiliations 4 and 17 have been corrected to reflect the proper institutional order. The publisher apologizes for the inconvenience caused.
  9. Operation of the trigger system for the ICARUS detector at Fermilab

    The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.
  10. Constraints on lepton number violation with the 2 tonne · year CUORE dataset

    Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay (0νββ) may help explain this asymmetry while unveiling the Majorana nature of the neutrino. The CUORE (Cryogenic Underground Observatory for Rare Events) experiment searches for 0νββ of 130Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of 0νββ and place a lower limit on the half-life of T1/2 > 3.5 × 1025 years (90% credibility interval) with over 2 tonne·years of TeO2 exposure. Finally, the tools and techniques developed for this result and the 5-year stable operation of nearly 1000more » detectors demonstrate crucial infrastructure for future-generation experiments capable of searching for 0νββ across multiple isotopes.« less
...

Search for:
All Records
Creator / Author
"Zucchelli, S."

Refine by:
Article Type
Availability
Journal
Creator / Author
Publication Date
Research Organization