Title: New limit on dark photon kinetic mixing in the 0.2 – 1.2     μ eV mass range from the Dark E-field Radio experiment

Journal Article · · Physical Review. D.

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24     μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Research Organization:
Univ. of California, Davis, CA (United States); Univ. of California, Oakland, CA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
NA0000979; SC0009999; SC0022313
OSTI ID:
2429106
Journal Information:
Physical Review. D., Journal Name: Physical Review. D. Journal Issue: 3 Vol. 110; ISSN PRVDAQ; ISSN 2470-0010
Publisher:
American Physical SocietyCopyright Statement
Country of Publication:
United States
Language:
English

References (23)

Electromagnetic Fields in Cavities book January 2009
Two U(1)'s and ϵ charge shifts journal January 1986
Design and operational experience of a microwave cavity axion detector for the 20 – 100 μ eV range
  • Al Kenany, S.; Anil, M. A.; Backes, K. M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 854 https://doi.org/10.1016/j.nima.2017.02.012
journal May 2017
The Measurement of Thermal Radiation at Microwave Frequencies journal July 1946
An improved synthetic signal injection routine for the Haloscope At Yale Sensitive To Axion Cold dark matter (HAYSTAC) journal May 2023
The local dark matter density journal May 2014
Dark matter local density determination: recent observations and future prospects journal October 2021
Dark matter local density determination based on recent observations journal February 2020
Search for dark photon dark matter: Dark E field radio pilot experiment journal July 2021
Dark photon limits: A handbook journal November 2021
Spectral signatures of axionlike dark matter journal February 2022
Large-scale microwave cavity search for dark-matter axions journal October 2001
Dark light, dark matter, and the misalignment mechanism journal November 2011
Radio for hidden-photon dark matter detection journal October 2015
Vector dark matter from inflationary fluctuations journal May 2016
HAYSTAC axion search analysis procedure journal December 2017
Plane wave integral representation for fields in reverberation chambers journal January 1998
Reverberation chambers a la carte: An overview of the different mode-stirring techniques journal January 2017
On the definition of the effective aperture of antennas journal March 1961
Statistical Model of an Undermoded Reverberation Chamber journal February 2006
An introduction to matched filters journal June 1960
Signal, Noise and Resolution in Position-Sensitive Detectors journal January 1974
Direct Detection of Dark Matter: A Critical Review journal February 2024