DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 108 $$\frac {n}{cm^{2}s}$$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Office of Workforce Development for Teachers & Scientists (WDTS); USDOE Office of Science (SC), Basic Energy Sciences (BES). Scientific User Facilities (SUF)
Grant/Contract Number:
AC05-00OR22725; SC0014664
OSTI ID:
2372984
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 1064; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (23)

TheXYZ-Difference Method with Polarized Neutrons and the Separation of Coherent, Spin Incoherent, and Magnetic Scattering Cross Sections in a Multidetector journal February 1993
Oriented graphite as a neutron monochromator journal November 1969
Advanced geometries for ballistic neutron guides
  • Schanzer, Christian; Böni, Peter; Filges, Uwe
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 529, Issue 1-3 https://doi.org/10.1016/j.nima.2004.04.178
journal August 2004
Optimization of elliptic neutron guides for triple-axis spectroscopy
  • Janoschek, M.; Böni, P.; Braden, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 613, Issue 1 https://doi.org/10.1016/j.nima.2009.10.164
journal January 2010
The CG1 instrument development test station at the high flux isotope reactor
  • Crow, Lowell; Robertson, Lee; Bilheux, Hassina
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 634, Issue 1 https://doi.org/10.1016/j.nima.2010.06.213
journal April 2011
Parabolic versus elliptic focusing – Optimization of the focusing design of a cold triple-axis neutron spectrometer by Monte-Carlo simulations
  • Komarek, A. C.; Böni, P.; Braden, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 647, Issue 1 https://doi.org/10.1016/j.nima.2011.04.022
journal August 2011
Upgrade of the primary spectrometer of the cold triple-axis spectrometer FLEX at the BER II reactor
  • Skoulatos, M.; Habicht, K.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 647, Issue 1 https://doi.org/10.1016/j.nima.2011.05.037
journal August 2011
The upgrade of the cold neutron three-axis spectrometer IN12 at the ILL
  • Schmalzl, K.; Schmidt, W.; Raymond, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 819 https://doi.org/10.1016/j.nima.2016.02.067
journal May 2016
Design of the cold neutron triple-axis spectrometer at the China Advanced Research Reactor
  • Cheng, P.; Zhang, Hongxia; Bao, W.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 821 https://doi.org/10.1016/j.nima.2016.03.045
journal June 2016
Optimizing the triple-axis spectrometer PANDA at the MLZ for small samples and complex sample environment conditions
  • Utschick, C.; Skoulatos, M.; Schneidewind, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 837 https://doi.org/10.1016/j.nima.2016.08.060
journal November 2016
A High Transmission Slow Neutron Velocity Selector journal February 1953
Superconducting magnetic Wollaston prism for neutron spin encoding journal May 2014
CAMEA—A novel multiplexing analyzer for neutron spectroscopy journal March 2016
Commissioning of the novel Continuous Angle Multi-energy Analysis spectrometer at the Paul Scherrer Institut journal February 2023
The joy of acceptance diagrams journal January 1993
Scientific Review: The Triple Axis Spin-Echo Spectrometer TRISP at the FRM II journal May 2007
ThALES—Three Axis Low Energy Spectroscopy for highly correlated electron systems journal July 2015
MACS—a new high intensity cold neutron spectrometer at NIST journal January 2008
Neutron polarimetry
  • Brown, P. Jane; Forsyth, J. B.; Tasset, F.
  • Proceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences, Vol. 442, Issue 1914, p. 147-160 https://doi.org/10.1098/rspa.1993.0096
journal July 1993
High-resolution phonon energy shift measurements with the inelastic neutron spin echo technique journal June 2019
Optimization of highly oriented pyrolytic graphite applied to neutron crystal optics journal February 2022
Simulation and Analysis of the Transmission Properties of Curved-Straight Neutron Guide Systems journal January 1992
McStas (ii): An overview of components, their use, and advice for user contributions journal April 2021

Similar Records

Neutron spin echo device to improve the energy resolution of triple axis spectrometers
Journal Article · 1982 · AIP Conf. Proc.; (United States) · OSTI ID:6384913

Monte–Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor
Journal Article · 2024 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:2426043

The triple axis and SPINS spectrometers
Journal Article · · Journal of Research of the National Institute of Standards and Technology; (United States) · OSTI ID:5825229