DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of source-location algorithms for atmospheric samplers

Journal Article · · Journal of Environmental Radioactivity

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-76RL01830
OSTI ID:
2282028
Report Number(s):
PNNL-SA--192017
Journal Information:
Journal of Environmental Radioactivity, Journal Name: Journal of Environmental Radioactivity Vol. 273; ISSN 0265-931X
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (24)

The АРИКС-01 Automatic Facility for Measuring Concentrations of Radioactive Xenon Isotopes in the Atmosphere journal May 2005
Multi-detection events, probability density functions, and reduced location area journal July 2015
SAUNA—a system for automatic sampling, processing, and analysis of radioactive xenon
  • Ringbom, A.; Larson, T.; Axelsson, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 508, Issue 3, p. 542-553 https://doi.org/10.1016/S0168-9002(03)01657-7
journal August 2003
Atmospheric xenon radioactive isotope monitoring journal January 2004
A replacement for simple back trajectory calculations in the interpretation of atmospheric trace substance measurements journal October 2002
Source estimation methods for atmospheric dispersion journal October 2007
Paradigms and commonalities in atmospheric source term estimation methods journal May 2017
Review: Untangling the influence of air-mass history in interpreting observed atmospheric composition journal February 2012
A review of source term estimation methods for atmospheric dispersion events using static or mobile sensors journal July 2017
Radioxenon detections in the CTBT international monitoring system likely related to the announced nuclear test in North Korea on February 12, 2013 journal February 2014
Utility of atmospheric transport runs done backwards in time for source term estimation journal July 2019
Source term estimation using multiple xenon isotopes in atmospheric samples journal August 2019
Bayesian source reconstruction of an anomalous Selenium-75 release at a nuclear research institute journal July 2020
Source type estimation using noble gas samples journal December 2020
6 months of radioxenon detection in western Europe with the SPALAX-New generation system - Part1: Metrological capabilities journal December 2020
Enabling probabilistic retrospective transport modeling for accurate source detection journal June 2022
Phase II testing of Xenon International on Mount Schauinsland, Germany journal December 2022
Projected network performance for next generation aerosol monitoring systems journal February 2023
Global emission inventory of 131mXe, 133Xe, 133mXe, and 135Xe from all kinds of nuclear facilities for the reference year 2014 journal May 2023
Atypical compounds of gases, which have been called ‘noble’ journal January 2007
NOAA’s HYSPLIT Atmospheric Transport and Dispersion Modeling System journal December 2015
Eulerian backtracking of atmospheric tracers. I: Adjoint derivation and parametrization of subgrid‐scale transport journal January 2006
Eulerian backtracking of atmospheric tracers. II: Numerical aspects journal January 2006
On the model uncertainties in Bayesian source reconstruction using an ensemble of weather predictions, the emission inverse modelling system FREAR v1.0, and the Lagrangian transport and dispersion model Flexpart v9.0.2 journal March 2021

Similar Records

Detecting 127Xe in an atmospheric tracer experiment
Journal Article · 2025 · Journal of Environmental Radioactivity · OSTI ID:2586434

Source term estimation using noble gas and aerosol samples
Journal Article · 2024 · Journal of Environmental Radioactivity · OSTI ID:2472798

A More Precise Measurement of the Radius of PSR J0740+6620 Using Updated NICER Data
Journal Article · 2024 · The Astrophysical Journal · OSTI ID:2476030